Heating and Cooling Chamber

Heating & Cooling Chamber

Environmental Test Chamber with Wide Temperature Range from -40°C to 150°C

The Heating & Cooling Chamber is designed for precise environmental control across a wide temperature range of -40°C to 150°C. It provides controlled heating and cooling conditions for critical applications including stability studies, R&D, pharmaceutical testing and other temperature-controlled laboratory applications.

Key Features & Benefits

  • Wide temperature range of -40°C to 150°C.
  • Reliable performance with GMP compliant design.
  • 7″ HMI colour touch screen with PLC-based control.
  • Data integrity and 21 CFR Part 11 compliance options.
  • Ideal for stability studies and R&D.
  • Microprocessor/PLC-based control system with PID control.
  • Programmable operation with up to 5 programs and 32 steps.
  • 10,000-reading offline data logger.
  • Ethernet communication.
  • Robust GMP-model construction with SS 304.
  • DQ, IQ, OQ and PQ support with calibration and test certificates.

Construction

  • Double walled, SS 304 construction with inner mirror finish and outer matt finish.
  • 3″ thick CFC-free PUF insulation.
  • Double door — inner full-view viewing door & outer insulated door with lock and key.
  • 50 mm validation port with silicon rubber seal.
  • Stainless steel rod trays with adjustable height.
  • Mounted on castor wheels with front lock arrangement.
  • Fluorescent light with auto ON/OFF on door operation.

Technical Specifications

Parameter Specification
Temperature Range -40°C to 150°C
Temperature Accuracy 1°C
Temperature Uniformity ± 2°C
Relative Humidity No RH
Ramp Up Time No Ramp Up Time facility, usually 0.3 to 0.7°C/min (depending upon heat load)
Temperature Sensor A-grade RTD (PT-100)
Temperature Resolution 0.1°C
Display 7" colour touch screen (Delta)
Control System PLC-based with 7" HMI, PID control
Data Logger Offline data logger with 10,000 reading storage
Communication Ethernet communication
Programmable Features 5 programs, up to 32 steps, repeat up to 999 times
Heating System U-shaped Nichrome heater (SS sheathing)
Cooling System Three compressors with R134a, R404 & R23 (cascade)
Air Circulation Flange motor with impeller & blower
Lighting Fluorescent light with auto ON/OFF on door operation
Protection IP 22

Heating & Cooling System

  • U-shaped Nichrome heater (SS sheathing).
  • Three compressors with R134a, R404 & R23 (cascade).
  • Bypass solenoid valve for high temperature.
  • Flange motor with impeller & blower.
  • Air circulation by motor & fan continuously recirculates air through heater, evaporator and back to chamber to achieve desired temperature stability.
  • The design reduces power consumption by 50%.

Safety Features

  • Temperature: Heater cut-off by thermostat, auto reset.
  • Humidity: Boiler cut-off, alarm & buzzer.
  • Low water level: Boiler cut-off with alarm.
  • Human safety: Individual MCBs, proper earthing.
  • Audio & visual alarms for temperature deviation.
  • Alarm for sensor failure.
  • Alarm for component failure.
  • Alarm for mains failure.
  • Alarm for door open.
  • Alarm for thermostat high.

Control & Monitoring System

  • PLC-based control system with 7″ HMI.
  • Offline data logger with storage of 10,000 readings.
  • Dot-matrix printer.
  • Relays, contactors and MCB.
  • PID control.
  • Ethernet communication.
  • IP 22 protection.
  • 7″ colour touch screen (Delta).
  • Set/process value display.
  • Alarm indication.
  • Graph display.
  • Password protection.
  • Multi-set point operation.

Programmable Features

  • 5 programs
  • Up to 32 steps
  • Repeat up to 999 times
  • Programmable output (TC1) available

Data Integrity & 21 CFR Part 11

  • 21 CFR Part 11 compliant software (optional).
  • Web-based software.
  • Audit trail & data log.
  • Unlimited users.
  • Multi-level login.
  • Temperature data history.
  • Alarm & data log.
  • Data log & alarm reports.
  • Password expiry & auto logout.
  • Connect up to 20 chambers.

Applications & Industries

  • Electronics & Semiconductor
  • Aerospace
  • Pharmaceuticals
  • Automobile
  • Packing
  • Medical Storage
  • R&D Activity

Models & Size Range

Standard Model GMP Model Cu. Ft. Litres Chamber
(W × D × H)
Overall
(W × D × H)
Unit Packed VAC/Hz Watts
PIS-3(40) PIS G-3(40) 3 90 45×45×45 60×95×110 2 110 230,50 1500
PIS-4(40) PIS G-4(40) 4 120 45×45×60 60×95×125 2 150 230,50 2000
PIS-8(40) PIS G-8(40) 8 200 60×60×60 80×110×125 2 220 230,50 2500
PIS-12(40) PIS G-12(40) 12 324 60×60×90 80×110×155 3 230 230,50 2500
PIS-16(40) PIS G-16(40) 16 450 60×60×125 80×130×175 4 340 230,50 4000
PIS-21(40) PIS G-21(40) 21 600 60×80×125 80×130×195 5 365 230,50 4000
PIS-28(40) PIS G-28(40) 28 800 80×80×125 100×130×210 5 390 230,50 4500
PIS-34(40) PIS G-34(40) 34 1000 80×80×155 100×130×220 5 430 230,50 4500

DQ, IQ, OQ, PQ & Documentation Support

  • DQ, IQ, OQ & PQ
  • Protocols
  • Calibration certificates
  • Test certificates
  • Manuals
  • Diagrams
  • Training

Why Choose Phoenix India Solutions (PIS)

  • Quality products from trusted manufacturers.
  • Application-oriented environmental chamber solutions.
  • Technical support & after-sales service.
  • Installation, validation & documentation support.
  • Support for DQ, IQ, OQ & PQ requirements.
  • Competitive pricing and quick delivery.
  • Your long-term partner in scientific growth.

Interested in This Heating & Cooling Chamber?

Get in touch with Phoenix India Solutions for Heating & Cooling Chamber specifications, temperature range requirements, technical discussions, validation support, pricing and quotation.

Scroll to Top