Fat Extraction System

Fat Extraction System for Soxhlet Extraction and Food Feed Analysis

Fat Extraction System

The Fat Extraction System is a laboratory extraction solution designed for efficient, safe and economical extraction of lipids and other soluble compounds from a wide range of samples. The system is suitable for applications involving food, feed, environmental and industrial samples.

The LABOSOX Extraction System – CME Classic Extraction combines Soxhlet extraction with controlled heating for efficient extraction of fat and oil from solid and semi-solid samples. It can be used for extraction of fat/oil in foods, feeds, soil, sludges, sediments and various industrial samples.

The system features high-quality borosilicate glassware, a digital temperature controller for precise heating, uniform heating for consistent results and a corrosion-resistant body. Individual heating control for each position is available as an optional feature.

The CME Classic Extraction System is available in 6-position and 12-position configurations. The system uses borosilicate glass Soxhlet extraction glassware and provides a temperature range from ambient to 300°C.

For routine fat and oil extraction, the system is suitable for samples including food, feed, dairy, meat, grain, soil and other applications. Extraction time can be reduced and solvent consumption can be controlled according to the extraction process.

Key Features & Benefits

  • 6 / 12 Position Configuration: Available in 6-position and 12-position configurations to support different sample throughput requirements.
  • Soxhlet Extraction Method: The CME Classic Extraction System uses the Soxhlet extraction method for extraction of fat and oil from solid and semi-solid samples.
  • High-Quality Borosilicate Glassware: The system is equipped with borosilicate glass extraction components for the extraction process.
  • Digital Temperature Controller: Digital temperature control provides precise heating during the extraction process.
  • Uniform Heating: Uniform heating is designed to support consistent extraction results across the sample positions.
  • Individual Heating Control: Individual heating control for each position is available as an optional feature.
  • Ambient to 300°C Temperature Range: The specified temperature range extends from ambient temperature to 300°C.
  • Corrosion-Resistant Body: The system features a corrosion-resistant body for laboratory extraction applications.
  • Robust Construction: The robust construction is designed for reliable laboratory operation and long service life.
  • Compact & Easy to Operate: The extraction system is designed for convenient laboratory operation with a compact configuration.
  • Controlled Solvent Consumption: The CME Classic system allows solvent consumption to be controlled during the extraction process.
  • Reduced Extraction Time: The product information states that extraction time can be reduced through the extraction process.
  • Wide Sample Compatibility: The system can be used for extraction of fat and oil from foods, feeds, soil, sludges, sediments and various industrial samples.
  • Precise & Reproducible Results: Controlled heating and uniform heating are designed to support precise and reproducible extraction results.

The Fat Extraction System combines Soxhlet extraction, borosilicate glassware and digital temperature control in a multi-position laboratory system for efficient extraction of fat, oil and other soluble compounds from suitable samples.

Technical Specifications

The LABOSOX CME – Classic Extraction System is available in 6-position and 12-position configurations for laboratory Soxhlet extraction applications.

Parameter CME – Classic Extraction
Sample Capacity 6 / 12 Position
Extraction Method Soxhlet Extraction
Glassware Borosilicate Glass
Heating Control Digital Temperature Controller
Heating Type Individual / Common (Optional)
Temperature Range Ambient to 300°C
Body Material Powder Coated Mild Steel
Power Supply 230V AC, 50Hz
Accessories Complete glass assembly with flasks, thimbles & condensers

Note: The brochure specifies the sample capacity as 6 / 12 positions and identifies individual or common heating as optional. No separate dimensions, overall weight, heating power or extraction recovery values are specified in the supplied product information.

Models & Capacity

The LABOSOX CME – Classic Extraction System is offered in two sample-capacity configurations: 6-position and 12-position. The selected configuration can be matched to the laboratory's required sample throughput and extraction workload.

Configuration Sample Positions Extraction Method Temperature Range
CME Classic – 6 Position 6 Soxhlet Extraction Ambient to 300°C
CME Classic – 12 Position 12 Soxhlet Extraction Ambient to 300°C

6-Position Fat Extraction System

The 6-position configuration is designed for laboratories requiring multi-sample Soxhlet extraction in a compact laboratory setup. It provides six extraction positions with digital temperature control and borosilicate glass extraction components.

12-Position Fat Extraction System

The 12-position configuration provides twelve extraction positions for laboratories requiring a higher number of samples to be processed within the same extraction setup. It uses the same specified Soxhlet extraction method and digital temperature-control concept.

Flexible Heating Configuration

The brochure specifies individual or common heating control as an optional configuration. This allows the heating arrangement to be considered according to the laboratory's extraction requirements.

Note: The supplied brochure does not provide separate dimensions, weight or electrical power values for the 6-position and 12-position configurations. These values should therefore be confirmed according to the selected configuration before quotation.

Applications & Laboratory Uses

The LABOSOX CME – Classic Extraction System is designed for Soxhlet extraction of fat, oil and other soluble compounds from a wide range of solid and semi-solid samples. The brochure identifies applications across food, feed, environmental and industrial testing.

  • Food & Feed Analysis: Suitable for fat/oil determination in food and feed samples.
  • Dairy Testing: Suitable for extraction applications involving dairy samples.
  • Meat & Poultry Testing: Designed for fat/oil extraction applications involving meat and poultry samples.
  • Grain, Seed & Oilseed Analysis: Suitable for extraction applications involving grains, seeds and oilseeds.
  • Soil Extraction: Can be used for extraction of soluble compounds from soil samples.
  • Sediment & Sludge Extraction: Suitable for extraction applications involving sediments and sludges.
  • Environmental Testing: The system is suitable for environmental extraction applications involving appropriate samples.
  • Industrial Testing: Can be used for extraction of soluble compounds from a variety of industrial samples.
  • Quality Control Laboratories: Suitable for routine extraction work in quality control laboratory environments.
  • Research & Development: Suitable for laboratory research and development applications involving Soxhlet extraction.

Wide Range of Sample Applications

The system can be used for extraction of fat and oil from foods, feeds, soil, sludges, sediments and various industrial samples. Its 6-position and 12-position configurations allow laboratories to select a suitable setup according to their sample-processing requirements.

Fat & Oil Extraction Applications

For routine fat and oil extraction, the system provides Soxhlet extraction with borosilicate glassware and digital temperature control. The brochure also states that extraction time can be reduced and solvent consumption can be controlled.

Application Note: The applications listed above are based on the supplied product information. Specific sample preparation procedures, solvents, extraction times and analytical standards are not specified in the brochure and should be confirmed according to the intended application.

Advanced Features, Operation & Extraction System Components

The LABOSOX CME – Classic Extraction System combines controlled heating, Soxhlet extraction glassware and a multi-position configuration for efficient laboratory extraction of fat, oil and other soluble compounds.

Heating & Temperature Control

  • Digital Temperature Controller: Digital temperature control is provided for precise heating during the extraction process.
  • Ambient to 300°C: The specified temperature range is from ambient temperature to 300°C.
  • Individual / Common Heating: Individual or common heating is available, with individual heating control for each position identified as an optional feature.
  • Uniform Heating: Uniform heating is designed to support consistent extraction results.

Extraction System & Glassware

  • Soxhlet Extraction: The CME Classic uses the Soxhlet extraction method.
  • Borosilicate Glassware: High-quality borosilicate glass is used for the extraction glassware.
  • Complete Glass Assembly: The specified accessories include a complete glass assembly with flasks, thimbles and condensers.
  • Multi-Position Configuration: The system is available in 6-position and 12-position configurations.

Construction & Operation

  • Corrosion-Resistant Body: The extraction system features a corrosion-resistant body.
  • Powder-Coated Mild Steel: The specified body material is powder-coated mild steel.
  • Main Power Switch: A main power switch with indicator is provided for convenient operation.
  • Compact Design: The system is designed to be compact and easy to operate.
  • Robust Construction: The robust construction is intended for long service life in laboratory operation.

Extraction Performance Features

  • Efficient Extraction: The CME Classic is described as providing quick and effective extraction of solid and semi-solid samples.
  • Fat & Oil Extraction: Designed for routine fat determination across a wide range of samples.
  • Controlled Solvent Consumption: Solvent consumption can be controlled during the extraction process.
  • Reduced Extraction Time: The product information states that extraction time can be reduced through the extraction process.
  • Precise & Reproducible Results: Uniform heating and controlled temperature operation are designed to support consistent extraction results.

The combination of Soxhlet extraction, borosilicate glassware, digital temperature control, multi-position operation and corrosion-resistant construction makes the CME Classic a practical laboratory solution for fat, oil and soluble-compound extraction applications.

Why Choose Phoenix India Solutions?

  • Laboratory Extraction Solution: Phoenix India Solutions supplies laboratory equipment and solutions for analytical, research, quality-control and testing requirements.
  • Dedicated Fat & Oil Extraction Solution: The LABOSOX CME Classic is designed specifically for extraction of fat, oil and other soluble compounds from suitable samples.
  • Soxhlet Extraction Technology: The system uses the Soxhlet extraction method with borosilicate glass extraction components.
  • 6 & 12 Position Options: The available 6-position and 12-position configurations provide flexibility for different sample-processing requirements.
  • Digital Temperature Control: A digital temperature controller provides controlled heating across the specified ambient to 300°C range.
  • Uniform Heating: The system is designed for uniform heating to support consistent extraction results.
  • Flexible Heating Configuration: Individual or common heating is available as specified, with individual heating control offered as an optional feature.
  • Quality Glassware: High-quality borosilicate glassware and a complete glass assembly with flasks, thimbles and condensers are specified.
  • Corrosion-Resistant Construction: The corrosion-resistant body and powder-coated mild-steel construction are designed for laboratory extraction environments.
  • Wide Sample Applications: The system can be used for extraction applications involving food, feed, dairy, meat, grain, soil, sediments, sludge and various industrial samples as identified in the product information.
  • Application-Based Support: Phoenix India Solutions can assist with configuration selection based on the required number of positions and intended extraction application.
  • Technical & Commercial Support: PIS can assist customers with product specifications, configuration selection, quotation and laboratory equipment requirements.

For laboratories looking for a Fat Extraction System or Soxhlet Extraction System in India, Phoenix India Solutions can provide the appropriate configuration based on sample throughput and extraction requirements.

Interested in Fat Extraction System?

Looking for a reliable Fat Extraction System for Soxhlet extraction and fat or oil determination in laboratory samples?

The LABOSOX CME – Classic Extraction System is available in 6-position and 12-position configurations and features borosilicate glassware, digital temperature control, uniform heating and a specified temperature range of ambient to 300°C.

The system is suitable for extraction applications involving food, feed, dairy, meat, grain, seed, oilseed, soil, sediment, sludge and industrial samples, as identified in the supplied product information.

Phoenix India Solutions can assist you with configuration selection, technical specifications and quotation according to your laboratory's sample throughput and extraction requirements.

Contact Phoenix India Solutions to discuss your Fat Extraction System, Soxhlet Extraction System or Fat & Oil Extraction requirements.

Scroll to Top