Karl Fischer Titrator
Karl Fischer titration is an accurate, rapid and efficient method for determining the water content in samples.
When the sample is titrated in the presence of SO₃, I₂, and an organic base, moisture from the sample extracted in the solvent, can be quantitatively estimated. Dry methanol is used as a solvent in Karl Fischer titration.
Key Features & Benefits
- Indicator-electrode (two-pin platinum) with constant polarizing current for precise endpoint detection.
- Low solvent requirement with specially designed hermetically sealed vessel.
- Calculated doses of Karl Fischer reagent added automatically as per selected stop criteria.
- Background signal correction through offset mode.
- Built-in reagent standardization by Water or Sodium Tartrate for titre factor/concentration (F).
- Teflon-based liquid handling path (tubing, valve & syringe with teflon plunger) ensures chemically inert and leak-proof system.
- Magnetic, adjustable-speed stirrer with efficient moisture extraction.
- Continuous monitoring and automatic neutralization of moisture leak in the vessel.
- Results including leak rate are displayed on backlit LCD and printed in a tabulated form
- Advanced microcontroller based, user-friendly design with interactive software & invalid entry protection.
- Quick interchangeable imported burette assemblies with intelligent recognition & validation factor.
- Large memory for method storage with GLP compliance.
- Sample name, ID, date & time, auto incremented run number & customer name on printouts.
- Quick monitoring & automatic neutralization of moisture leak into vessel.
- End point delay up to 100 sec for slow moisture releasing samples.
- On line leak rate correction.
- Microcontroller based variable speed magnetic stirrer with digital indication.
- High accuracy & sensitivity.
- Rapid determination.
- GLP & 21 CFR Part 11 compliant.
- User friendly & reliable.
- Teflon-based liquid handling path for a chemically inert and leak-proof system.
- Built-in reagent standardization by Water or Sodium Tartrate for titre factor/concentration (F).
- Automatic addition of calculated Karl Fischer reagent doses according to selected stop criteria.
Technical Specifications
| Parameter | Specification |
|---|---|
| Calculation Modes | Weight / Weight Volume / Volume Volume / Density |
| Report Formats | Report giving titration parameter & result Report of method parameters Condensed report of titration parameter & result Graph printout of reaction trend |
| Endpoint Detection | Indicator-electrode (two-pin platinum) with constant polarizing current |
| Endpoint Delay | Up to 100 sec for slow moisture releasing samples |
| Modes of Operation | Minimum Dose Mode / Drift Mode |
| Memory | Large memory for method storage with GLP compliance |
| Liquid Handling Path | Teflon-based liquid handling path with teflon plunger |
| Stirrer | Microcontroller based variable speed magnetic stirrer with digital indication |
| Reagent Standardization | Water or Sodium Tartrate for titre factor/concentration (F) |
| Balance Interface | Direct transfer of sample weight |
| Data & Reporting | Audit trail, electronic records, report generation & printing |
| Compliance | GLP, ASTM & 21 CFR Part 11 |
Modes of Operation
Minimum Dose Mode
The titration is stopped when the mV does not rise above the stop band in specified delay time.
Drift Mode
The titration is stopped if the calculated drift value is less than or equal to entered default value in µL/min.
Calculation & Reporting
Calculation Modes
- Weight / Weight
- Volume / Volume
- Volume / Density
Reporting Features
- Reports can be obtained even after resetting / power off / power failure.
- Static function – Mean, S.D., R.S.D. & C.V. of last 10 repeat run results.
- ASTM standard compliant for oil samples.
- Date & Time display & report printout with run time indication.
- Balance interface to directly transfer sample weight.
Selectable Report Formats (GLP compliant)
- Report giving titration parameter & result
- Report of method parameters
- Condensed report of titration parameter & result
- Graph printout of reaction trend
21 CFR Part 11 Compliance
- Audit Trail for all activities with search facility, report generation & printing
- 200 User ID’s with alphanumeric entries (User name, password & role based privileges)
- Multi-level roles with password protection
- User authentication for each operation
- Customizable PDF report file creation
- USB Printing & WiFi Printing
- Electronic signature functionality
- Manual archive & data backup facility
Applications
- Pharmaceutical
- Food & Beverages
- Petrochemicals
- Cosmetics
- Organic / Inorganic Chemicals & more
Why Choose Phoenix India Solutions (PIS)
- Application-focused selection of Karl Fischer titration systems based on your moisture analysis requirements.
- Support for pharmaceutical, food & beverage, petrochemical, cosmetic and chemical laboratory applications.
- Technical assistance for moisture determination and Karl Fischer titration requirements.
- Support for instrument selection, technical discussions and quotations.
- Complete documentation and coordination with the manufacturer.
- Responsive after-sales assistance and service coordination.
Interested in This Karl Fischer Titrator?
Get in touch with Phoenix India Solutions for Karl Fischer Titrator specifications, moisture analysis requirements, technical discussions, pricing and quotation.