Biological Safety Cabinet
Class II Type A2 Biological Safety Cabinet for Laboratory & Research Applications
We design and supply Class 2 Biosafety Cabinets Type A2 for laboratory and research applications.
These Type A2 Class II Biological Safety Cabinets have an open front design provided with negative pressure generation module. Type A2 cabinets are typically used for biosafety levels 1 through 3 and are suitable for work with chemicals, as long as vapors are not hazardous and will not interfere with the work when recirculated. Cabinets protect from contamination of the works, experiment or process from outside contaminants.
The ergonomic internal design, the airflow aerodynamics, the built-in safety devices and the advanced level of construction, ensure the highest performances and the most stringent safety levels, as specified by International standards.
Protection
- Personnel Protection — Protection from harmful agents
- Product Protection — Prevents contamination of your work
- Environment Protection — Protects environment from contamination
Applicable Standards
- NSF/ANSI 49 — USA Standard
- EN 12469 — European Guidelines
- ISO 14644-1 — Cleanroom & controlled environment classification
Key Features & Benefits
- A front access opening with carefully maintained inward air flow.
- Approximately 70% of air is recirculated through HEPA filter back to work area, 30% exhausted through HEPA filter.
- Room air enters through pre-filter and HEPA filter as vertical unidirectional airflow.
- Negative pressure maintains inward air flow in chamber.
- Work table at a height of 760 mm for comfortable sitting position.
- Aerodynamic airflow grills prevent blockage.
- High efficiency pre-filter increases HEPA filter life.
- Manufactured as per NSF/ANSI 49 USA standard, EN 12469 European guidelines and ISO 14644-1.
- Brushless DC Blower / Motor.
- HEPA Filtered Exhaust.
- UV Germicidal Sterilization.
- Ergonomic Design.
- Low noise operation — less than 62 dB ±3 dB.
- Digital Controller — Optional.
Optional Features:
- Analog Manometric Gauge (Dial Type) in lieu of manometer gauge
- Digital Manometric gauge with electronic filter choke alarm
- Inclined manometer or magnetic gauge to monitor pressure across HEPA filter
- Interlocking of UV germicidal tube with auto switch off UV light when door is opened
- Microprocessor LCD controller with digital display for status indication of ON/OFF – Blower, ON/OFF – UV Lamp & ON/OFF – LED Lamp
- Blower failure status indication
- Door alarm when sash is opened above safe height of 8″
- ULPA filter having 99.97% efficient at 0.1 to 0.3 micron particulates for ISO class 4 work cleanliness condition
- Hour meter for totalizing UV light burning hours
- UV light timer for automatic ON/OFF cycle of chamber sterilization
Technical Specifications
| Parameter | Specification |
|---|---|
| Main Filter | HEPA Filter — 99.99% efficient at 0.3 micron particulate for air quality ISO 5 Class 100 |
| Pre-filter | High-efficiency washable pre filter having efficiency 90% down to 5 micron |
| Illumination | LED light of 5/10/15/20 W (greater than 1200 Lux as per standard guidelines) |
| Front Door | UV Germicidal Tube of 254 nm wavelength |
| Utility | Sliding type safety door made of special laminated glass frame with counter balanced weight mechanism |
| Pressure Gauge | Gas/Air cock and Multipoint 15/5 Amp. electric socket |
| Flow Velocity | Inclined Manometer Gauge (red oil filled) to monitor main HEPA filter pressure drop; Inflow 0.5 m/s (100 fpm); Downflow 0.3 m/s (60 fpm) |
| MOC Outer Cabinet | Cold Rolled Steel Powder Coated (Optional Stainless Steel SS-304) |
| MOC Inner Cabinet | Walls — single piece jointless SS 304 sheet with rounded corners |
| Work Table | Top — perforated SS 304 grill for filter protection; Stainless Steel 304 grade (Optional Stainless Steel SS-316) |
| Digital Controller | Optional |
Models & Size Range
| Model | Work Area (W × D × H) | Overall Size (W × D × H) |
|---|---|---|
| SAIF-BSC-A2-2 | 2 × 2 × 2 | 2.4 × 2.7 × 6.9 |
| SAIF-BSC-A2-3 | 3 × 2 × 2 | 3.4 × 2.7 × 6.9 |
| SAIF-BSC-A2-4 | 4 × 2 × 2 | 4.4 × 2.7 × 6.9 |
| SAIF-BSC-A2-5 | 5 × 2 × 2 | 5.4 × 2.7 × 6.9 |
| SAIF-BSC-A2-6 | 6 × 2 × 2 | 6.4 × 2.7 × 6.9 |
Applications & Industries
- Pharmaceutical Laboratories
- Microbiology Laboratories
- Research & Development Laboratories
- Biotechnology Laboratories
- Quality Control Laboratories
- Clinical & Diagnostic Laboratories
- Life Science Laboratories
- Educational & Research Institutions
Why Choose Phoenix India Solutions
- Application-focused selection of microbiology laboratory instruments based on your laboratory requirements.
- Support for Biological Safety Cabinet selection, technical discussions and quotations.
- Assistance with laboratory solutions for microbiology, pharmaceutical, research and quality-control applications.
- Complete documentation and coordination with the manufacturer.
- Responsive after-sales assistance and service coordination.
Interested in This Biological Safety Cabinet?
Get in touch with Phoenix India Solutions for Biological Safety Cabinet specifications, technical discussions, pricing and quotation.